Optical Power Ground Wire for Transmission Applications
Using good stainless steel tube production technology, the tube is filled with water blocking compounds, which can effectively protect the optical fiber
Good compactness and high tensile strength
The short-circuit current has little mutual interference between the power grid and the communication network
Similar to the common ground wire specifications, it is very convenient to erect and can directly replace the original ground wire
OPGW optical cable is to place the optical fiber in the ground wire of the overhead high-voltage transmission line to form the optical fiber communication network on the transmission line. This structure has the dual functions of ground wire and communication. The optical power ground wire is more reliable, stable and firm due to the metal wire wrapping. Because the overhead ground wire and the optical cable are combined as a whole, compared with other methods of optical cables, the construction period is shortened and the construction cost is saved.
OPGW Optical Cable Characteristics & Advantage
Using good stainless steel tube production technology, the tube is filled with water blocking compounds, which can effectively protect the optical fiber
Good compactness and high tensile strength
The short-circuit current has little mutual interference between the power grid and the communication network
Similar to the common ground wire specifications, it is very convenient to erect and can directly replace the original ground wire
OPGW with PBT Aluminum Tube
The PBT Loose Tube Optical Ground Wire (OPGW) is surrounded by single or double layers of aluminum clad steel wires(ACS) or mix ACS wires and aluminum alloy wires. Good anti-corrosion performance.Material and structure are uniform, good resistance to vibration fatigue.
Product Name: PBT Loose Buffer Tube Type OPGW
Fiber Type: G652D; G655C; 657A1; 50/125; 62.5/125; OM3; OM4 As Options
Fiber Count: 2-72 Core
Applications: Reconstruction of old power lines and low voltage level lines. Coastal chemical industrial areas with heavy chemical pollution.
OPGW Typical Designs of Stranded Stainless Steel Tube
OPGW Mainly used for power communication with accessories,relay protection,automatic transmission,installation together with high-voltage lines.
The Stranded Optical Ground Wire (OPGW) is stranded by double or three layers of aluminum clad steel wires(ACS) or mix ACS wires and aluminum alloy wires, Its design is fully adapted to the most common electric line needs.
Fiber Type: G652D; G655C; 657A1; 50/125; 62.5/125; OM3; OM4 As Options
Fiber Count: Up to 96 Cores
Applicable Voltage Range: Power lines with voltage level of 110KV and below.
Applications: Commonly used in newly built overhead power lines. Can meet the requirements of big number of fibers and ultra high voltage(UHV)transmission lines. Can provide protection against lightning by transmitting large fault short-circuit current
OPGW Typical Designs of Central AL-covered Stainless Steel Tube
OPGW Mainly used for power communication with accessories,relay protection,automatic transmission,installation together with high-voltage lines. The central AL-covered steel tube is surrounded by single or double layers of aluminum clad steel wires(ACS) or mix ACS wires and aluminum alloy wires.AL-covered Stainless Steel Tube design increases the cross section of AL,to reach a better fault current and lightning resistance performance.Apply to the transmission line which requires small diameter and large fault current.
Fiber Type: G652D; G655C; 657A1; 50/125; 62.5/125; OM3; OM4 As Options
Applications:Aerial, Overhead, Outdoor
Applicable Voltage Range: Power lines with voltage level of 220KV and above.
Applications:
Reconstruction of old power lines and low voltage level lines.
Coastal chemical industrial areas with heavy chemical pollution.
OPGW Typical Designs of Central Stainless Steel Loose Tube
OPGW Mainly used for power communication with accessories,relay protection,automatic transmission,installation together with high-voltage lines.
The central stainless steel tube is surrounded by single or double layers of aluminum clad steel wires(ACS) or mix ACS wires and aluminum alloy wires. are the most widely used cables ,their design is fully adapted to the most common electric line needs.
Fiber Type: G652D; G655C; 657A1; 50/125; 62.5/125; OM3; OM4 As Options
Applications:
Replacement of existing ground wires and reconstruction of old lines.
Applicable to low-grade lines, such as GJ50/70/90 and etc.
OPGW with PBT Aluminum Tube
Specification | Fiber Count | Diameter(mm) | Weight (kg/km) | RTS(KN) | Short Circuit(KA2s) |
OPGW-113(87.9;176.9) | 48 | 14.8 | 600 | 87.9 | 176.9 |
OPGW-70(81; 41) | 24 | 12 | 500 | 81 | 41 |
OPGW-66(79;36) | 36 | 11.8 | 484 | 79 | 36 |
OPGW-77(72;36) | 36 | 12.7 | 503 | 72 | 67 |
OPGW Typical Designs of Stranded Stainless Steel Tube
Typical design for Double Layer:
Specification | Fiber Count | Diameter(mm) | Weight (kg/km) | RTS(KN) | Short Circuit (KA2s) |
OPGW-89[55.4;62.9] | 24 | 12.6 | 381 | 55.4 | 62.9 |
OPGW-110[90.0;86.9] | 24 | 14 | 600 | 90 | 86.9 |
OPGW-104[64.6;85.6] | 28 | 13.6 | 441 | 64.6 | 85.6 |
OPGW-127[79.0;129.5] | 36 | 15 | 537 | 79 | 129.5 |
OPGW-137[85.0;148.5] | 36 | 15.6 | 575 | 85 | 148.5 |
OPGW-145[98.6;162.3] | 48 | 16 | 719 | 98.6 | 162.3 |
Typical design for Three Layer:
Specification | Fiber Count | Diameter(mm) | Weight (kg/km) | RTS(KN) | Short Circuit (KA2s) |
OPGW-232[343.0;191.4] | 28 | 20.15 | 1696 | 343 | 191.4 |
OPGW-254[116.5;554.6] | 36 | 21 | 889 | 116.5 | 554.6 |
OPGW-347[366.9;687.7] | 48 | 24.7 | 2157 | 366.9 | 687.7 |
OPGW-282[358.7;372.1] | 96 | 22.5 | 1938 | 358.7 | 372.1 |
OPGW Typical Designs of Central AL-covered Stainless Steel Tube
Typical Design for Single Layer
Specification | Fiber Count | Diameter(mm) | Weight (kg/km) | RTS(KN) | Short Circuit(KA2s) |
OPGW-80(82.3;46.8) | 24 | 11.9 | 504 | 82.3 | 46.8 |
OPGW-70(54.0;8.4) | 24 | 11 | 432 | 70.1 | 33.9 |
OPGW-80(84.6;46.7) | 48 | 12.1 | 514 | 84.6 | 46.7 |
Typical Design for Double Layer
Specification | Fiber Count | Diameter(mm) | Weight (kg/km) | RTS(KN) | Short Circuit(KA2s) |
OPGW-143(87.9;176.9) | 36 | 15.9 | 617 | 87.9 | 176.9 |
OPGW Typical Designs of Central Stainless Steel Loose Tube
Typical design for Single Layer:
Specification | Fiber Count | Diameter (mm) | Weight (kg/km) | RTS (KN) | Short Circuit (KA2s) |
OPGW-32(40.6;4.7) | 12 | 7.8 | 243 | 40.6 | 4.7 |
OPGW-42(54.0;8.4) | 24 | 9 | 313 | 54 | 8.4 |
OPGW-42(43.5;10.6) | 24 | 9 | 284 | 43.5 | 10.6 |
OPGW-54(55.9;17.5) | 36 | 10.2 | 394 | 67.8 | 13.9 |
OPGW-61(73.7;175) | 48 | 10.8 | 438 | 73.7 | 17.5 |
OPGW-61(55.1;24.5) | 48 | 10.8 | 358 | 55.1 | 24.5 |
OPGW-68(80.8;21.7) | 54 | 11.4 | 485 | 80.8 | 21.7 |
OPGW-75(54.5;41.7) | 60 | 12 | 459 | 63 | 36.3 |
OPGW-76(54.5;41.7) | 60 | 12 | 385 | 54.5 | 41.7 |
Typical design for Double Layer:
Specification | Fiber Count | Diameter (mm) | Weight (kg/km) | RTS (KN) | Short Circuit (KA2s) |
OPGW-96(121.7;42.2) | 12 | 13 | 671 | 121.7 | 42.2 |
OPGW-127(141.0;87.9) | 24 | 15 | 825 | 141 | 87.9 |
OPGW-127(77.8;128.0) | 24 | 15 | 547 | 77.8 | 128 |
OPGW-145(121.0;132.2) | 28 | 16 | 857 | 121 | 132.2 |
OPGW-163(138.2;183.6) | 36 | 17 | 910 | 138.2 | 186.3 |
OPGW-163(99.9;213.7) | 36 | 17 | 694 | 99.9 | 213.7 |
OPGW-183(109.7;268.7) | 48 | 18 | 775 | 109.7 | 268.7 |
OPGW-183(118.4;261.6) | 48 | 18 | 895 | 118.4 | 261.6 |