NavigationNAV
XLPE Insulated Control Cables
 1

XLPE Insulated Control Cables

Send Inquiry
Description

XLPE Insulated Multicore Control Cables

Has excellent properties of resistant to high temperature, aging, oil and radiation and is flexible. 

Has the properties of wide use, water-proof, resistance to oil, acid, alkali and wearing and all kinds of chemical gent(except the chloroform),hard to cause burning etc. 

XLPE insulated Control Cables

KYJV (N2XY)

CU/XLPE/PVC

KYJVP (N2XCY)

CU/XLPE/CWS/PVC

KYJVP2 (N2XSY)

CU/XLPE/CTS/PVC

KYJV22 (N2XBY)

CU/XLPE/STA/PVC

KYJV32 (N2XRGBY)

CU/XLPE/SWA/PVC

XLPE insulated control cables are often used to connect various electrical appliances, instruments and automatic devices, suitable for control and monitor circuit and circuit protection under the condition that the AC rated voltage lower than 600/1000V.

Operating characteristics and electrical performance

1.Cable laying temperature: ≥0°C

2.Long-term allowable operating temperature of cable conductor: 90°C

3.Minimum permissible bending radius:

a.For unarmored cables, should be no less than 6 times of cable outer diameter;

b.For armored or copper belt shield structure cables, should be not less than 12 times of cable outer diameter;

c.For flexible cable with shield structure, shoud be less than six times of cable outer diameter.

4.Finished cable can bear AC 50HZ, 3 KV, 5min withstand test without breakdown.

5.Conductor DC resistance meets the requirements of national standard GB/T3956-2008 “Cable Conductor” and international standard IEC60228.

23XLPE insulate control cable 1.jpg

Operating characteristics and electrical performance

1.Cable laying temperature: ≥0°C

2.Long-term allowable operating temperature of cable conductor: 90°C

3.Minimum permissible bending radius:

a.For unarmored cables, should be no less than 6 times of cable outer diameter;

b.For armored or copper belt shield structure cables, should be not less than 12 times of cable outer diameter;

c.For flexible cable with shield structure, shoud be less than six times of cable outer diameter.

4.Finished cable can bear AC 50HZ, 3 KV, 5min withstand test without breakdown.

5.Conductor DC resistance meets the requirements of national standard GB/T3956-2008 “Cable Conductor” and international standard IEC60228.

Models, Names and Laying Occasions of XLPE Insulated Control Cable 

Model

Name

Laying Occasion

KYJV

Copper core XLPE insulated PVC sheathed control cable

Laid indoors, and in cable trenches, pipelines and other fixed occasions.

KYJVP

Copper core XLPE insulated PVC sheathed braid shield control cable

Laid indoors, and in cable trenches, pipelines and other fixed occasions requiring shielding.

KYJVP2

Copper core XLPE insulated PVC sheathed copper belt shield control cable

Laid indoors, and in cable trenches, pipelines and other fixed occasions requiring shielding.

KYJV22

Copper core XLPE insulated PVC sheathed steel tape armored control cable

Laid indoors, and in cable trenches, pipelines, direct-buring and other fixed places capable of bearing large mechanical force.

KYJV32

KYJV32 Copper core XLPE insulated PVC sheathed fine steel wire armored control cable

Laid indoors, and in cable trenches, pipelines, vertical shafts and other fixed places capable of bearing large mechanical force.

KYJVR

Copper core XLPE insulated PVC sheathed flexible control cable

Laid indoors in occasions requiring movement and flexibility.

KYJVRP

Copper core XLPE insulated PVC sheathed braid shielding control cable

Laid indoors in occasions requiring movement, flexibility and shielding.

KYJVP2-22

Copper core XLPE insulated PVC sheathed steel tape shielded steel plate armored control cable

Laid indoors, and in cable trenches, pipelines and other fixed occasions capable of bearing large mechanical force and requiring shielding.

Range of production

 

 

Model

Rated voltage (V)

Conductor nominal cross sectional area (mm2)

 

0.75

1.0

1.5

2.5

4

6

10

KYJV

 

 

 

 

45O/750

-

2-61

2-14

2-10

KYJVP

KYJP2

 

4-61

4-14

4-10

KYJV22

-

7-61

4-61

4-14

4-10

KYJVP2-22

KYJV32

-

19-61

7-61

4-14

4-10

KYJVR

 

4-61

-

-

KYJVRP

4-61

4-48

-

-

Notes: The recommended number of cores is: 2, 3, 4, 5, 7, 8, 10, 12, 14, 16, 19, 24, 27, 37, 44, 48, 52 and 61


Standard

Please fill in your procurement needs and contact information.